The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

§ 98.30-15 Ground connection.

No person may transfer an inflammable or combustible product to or from a vessel unless—

(a) The portable tank or IBC and its pumping equipment is electrically grounded to the hull of the vessel; and

(b) The vessel is electrically grounded to an offshore platform, shore piping, or another vessel by a—

(1) Cargo hose constructed with an integral grounding wire if the end connections are used for electrical continuity; or

(2) Separate grounding that is maintained until the cargo hose is disconnected and drained.

[CGD 73-172, 39 FR 22954, June 25, 1974. Redesignated and amended by USCG-2011-0088, 78 FR 54785, 54787 Sept. 6, 2013]