The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

§ 432.62 Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:

(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:

Effluent Limitations

[BPT]

Regulated
parameter
Maximum daily 1 Maximum monthly avg. 1
BOD5 0.036 0.018
Fecal Coliform (2) (3)
O&G 4 0.012 0.006
TSS 0.044 0.022
1 Pounds per 1000 lbs (or g/kg) of finished product.
2 Maximum of 400 MPN or CFU per 100 mL at any time.
3 No maximum monthly average limitation.
4 May be measured as hexane extractable material (HEM).

(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS specified in paragraph (a) of this section.