The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

Subpart R—Secondary Mercury Subcategory

Source:

50 FR 38354, Sept. 20, 1985, unless otherwise noted.

§ 421.200 Applicability: Description of the secondary mercury subcategory.

The provision of this subpart are applicable to discharges resulting from the production of mercury from secondary mercury facilities processing recycled mercuric oxide batteries and other mercury containing scrap raw materials.

§ 421.201 Specialized definitions.

For the purpose of this subpart the general definitions, abbreviations, and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

§§ 421.202-421.203 [Reserved]

§ 421.204 Standards of performance for new sources.

Any new source subject to this subpart shall achieve the following new source performance standards:

(a) Spent battery electrolyte.

NSPS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of mercury produced from batteries
Lead 0.030 0.014
Mercury 0.016 0.006
Total suspended solids 1.590 1.272
pH (1) (1)
1 Within the range of 7.5 to 10.0 at all times.

(b) Acid wash and rinse water.

NSPS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of mercury washed and rinsed
Lead 0.00056 0.00026
Mercury 0.00030 0.00012
Total suspended solids 0.03000 0.02400
pH (1) (1)
1 Within the range of 7.5 to 10.0 at all times.

(c) Furnace wet air pollution control.

NSPS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of mercury processed through furnace
Lead 0.000 0.000
Mercury 0.000 0.000
Total suspended solids 0.000 0.000
pH (1) (1)
1 Within the range of 7.5 to 10.0 at all times.

§ 421.205 [Reserved]

§ 421.206 Pretreatment standards for new sources.

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in secondary mercury process wastewater introduced into a POTW shall not exceed the following values:

(a) Spent battery electrolyte.

PSNS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of mercury produced from batteries
Lead 0.030 0.014
Mercury 0.016 0.006

(b) Acid wash and rinse water.

PSNS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of mercury washed and rinsed
Lead 0.00056 0.00026
Mercury 0.00030 0.00012

(c) Furnance wet air pollution control.

PSNS for the Secondary Mercury Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds of mercury processed through furnace
Lead 0.000 0.000
Mercury 0.000 0.000

§ 421.207 [Reserved]