Site Feedback

Title 40

Displaying title 40, up to date as of 11/13/2026. Title 40 was last amended 11/13/2026.
eCFR Content

The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

Table W-6 to Subpart W of Part 98—Default Methane Leaker Emission Factors

Equipment components Emission
factor (scf methane/hour/
component)
If you survey using Method 21 as specified in § 98.234(a)(2)(i) If you survey using Method 21 as specified in § 98.234(a)(2)(ii) If you survey using any of the methods in § 98.234(a)(1), (3), or (5)
Leaker Emission Factors—LNG Storage and LNG Import and Export Equipment—Storage Components and Terminals Components, LNG Service
Valve 1.19 0.23 1.94
Pump Seal 4.00 0.73 6.54
Connector 0.34 0.11 0.56
Other 1 1.77 0.99 2.9
Leaker Emission Factors—LNG Storage and LNG Import and Export Equipment—Storage Components and Terminals Components, Gas Service
Valve 2 14.84 9.51 24.2
Connector 5.59 3.58 9.13
Open-Ended Line 17.27 11.07 28.2
Pressure Relief Valve 39.66 25.42 64.8
Meter and Instrument 19.33 12.39 31.6
Other 3 4.1 2.63 6.70
Leaker Emission Factors—Natural Gas Distribution—Transmission-Distribution Transfer Station 4 Components, Gas Service
Connector 1.69 2.76
Block Valve 0.557 0.91
Control Valve 9.34 15.3
Pressure Relief Valve 0.27 0.44
Orifice Meter 0.212 0.35
Regulator 0.772 1.26
Open-ended Line 26.131 42.7
1 “Other” equipment type for components in LNG service should be applied for any equipment type other than connectors, pumps, or valves.
2 Valves include control valves, block valves and regulator valves.
3 “Other” equipment type for components in gas service should be applied for any equipment type other than valves, connectors, flanges, open-ended lines, pressure relief valves, and meters and instruments, as specified in § 98.232(g)(6) and (7) and § 98.232(h)(7) and (8).
4 Excluding customer meters.

[89 FR 42327, May 14, 2024]