The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

Title 30Mineral ResourcesPart / Section
Chapter IMine Safety and Health Administration, Department of Labor1 – 199
Subchapter KMetal and Nonmetal Mine Safety and Health56 – 58
Part 57Safety and Health Standards—Underground Metal and Nonmetal Mines57.1 – 57.23004
Subpart KElectricity57.12001 – 57.12088
Surface and Underground57.12001 – 57.12053
§ 57.12001Circuit overload protection.
§ 57.12002Controls and switches.
§ 57.12003Trailing cable overload protection.
§ 57.12004Electrical conductors.
§ 57.12005Protection of power conductors from mobile equipment.
§ 57.12006Distribution boxes.
§ 57.12007Junction box connection procedures.
§ 57.12008Insulation and fittings for power wires and cables.
§ 57.12010Isolation or insulation of communication conductors.
§ 57.12011High-potential electrical conductors.
§ 57.12012Bare signal wires.
§ 57.12013Splices and repairs of power cables.
§ 57.12014Handling energized power cables.
§ 57.12016Work on electrically-powered equipment.
§ 57.12017Work on power circuits.
§ 57.12018Identification of power switches.
§ 57.12019Access to stationary electrical equipment or switchgear.
§ 57.12020Protection of persons at switchgear.
§ 57.12021Danger signs.
§ 57.12022Authorized persons at major electrical installations.
§ 57.12023Guarding electrical connections and resistor grids.
§ 57.12025Grounding circuit enclosures.
§ 57.12026Grounding transformer and switchgear enclosures.
§ 57.12027Grounding mobile equipment.
§ 57.12028Testing grounding systems.
§ 57.12030Correction of dangerous conditions.
§ 57.12032Inspection and cover plates.
§ 57.12033Hand-held electric tools.
§ 57.12034Guarding around lights.
§ 57.12035Weatherproof lamp sockets.
§ 57.12036Fuse removal or replacement.
§ 57.12037Fuses in high-potential circuits.
§ 57.12038Attachment of trailing cables.
§ 57.12039Protection of surplus trailing cables.
§ 57.12040Installation of operating controls.
§ 57.12041Design of switches and starting boxes.
§ 57.12042Track bonding.
§ 57.12045Overhead powerlines.
§ 57.12047Guy wires.
§ 57.12048Communication conductors on power poles.
§ 57.12050Installation of trolley wires.
§ 57.12053Circuits powered from trolley wires.
Surface Only57.12065 – 57.12071
§ 57.12065Short circuit and lightning protection.
§ 57.12066Guarding trolley wires and bare powerlines.
§ 57.12067Installation of transformers.
§ 57.12068Locking transformer enclosures.
§ 57.12069Lightning protection for telephone wires and ungrounded conductors.
§ 57.12071Movement or operation of equipment near high-voltage powerlines.
Underground Only57.12080 – 57.12088
§ 57.12080Bare conductor guards.
§ 57.12081Bonding metal pipelines to ground return circuits.
§ 57.12082Isolation of powerlines.
§ 57.12083Support of power cables in shafts and boreholes.
§ 57.12084Branch circuit disconnecting devices.
§ 57.12085Transformer stations.
§ 57.12086Location of trolley wire.
§ 57.12088Splicing trailing cables.