The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

§ 56.19021 Minimum rope strength.

At installation, the nominal strength (manufacturer's published catalog strength) of wire ropes used for hoisting shall meet the minimum rope strength values obtained by the following formulas in which “L” equals the maximum suspended rope length in feet:

(a) Winding drum ropes (all constructions, including rotation resistant).

For rope lengths less than 3,000 feet:

Minimum Value = Static

Load × (7.0-0.001L)

For rope lengths 3,000 feet or greater:

Minimum Value = Static Load × 4.0

(b) Friction drum ropes.

For rope lengths less than 4,000 feet:

Minimum Value = Static

Load × (7.0-0.0005L)

For rope lengths 4,000 feet or greater:

Minimum Value = Static Load × 5.0

(c) Tail ropes (balance ropes).

Minimum Value = Weight of Rope × 7.0