The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

Subpart D—Certification of Vessels' Cargo Gear

§ 1919.13 General.

(a) Except as noted in § 1919.1 and as provided in exemptions under § 1919.10(h), certification performed by accredited persons shall conform to the requirements contained in this subpart.

(b) Safe working loads assigned to assembled units of gear, shall be based on applicable design criteria acceptable to the accredited person. Where no design data on which to base a rating is obtainable, the safe working load ratings assigned shall be based on the owner's information and warranty that those so assigned are correct. Unit test certificates shall state the basis for any such safe working load assignment.

§ 1919.14 Initial tests of cargo gear and tests after alterations, renewals or repairs.

(a)

(1) Before being taken into use, hoisting machines, fixed gear aboard vessels accessory thereto, and loose gear and wire rope used in connection therewith shall be tested and examined and the safe working load thereof certified in the manner set forth in subpart E of this part.

(2) Replacement or additional loose gear and wire rope obtained from time to time shall also be tested and examined in the manner set forth in paragraph (a)(1) of this section. However, the replacement of a component part of an article of loose gear such as a sheave, pin, or bushing does not require a new test certificate as long as the new component at least equals in all particulars the part replaced.

(b) In the case of untested gear which has been in use, an initial test in conformance with paragraph (a)(1) of this section shall be carried out: Provided, however, That existing standing rigging and wire rope will not be required to be tested but shall be thoroughly examined to ascertain its fitness for continued use in conformance with the requirements of §§ 1919.24 and 1919.25.

(c) In the case of important alterations or renewals of the machinery and gear and also after repairs due to failure of or damage to other than loose components, a test as required in paragraph (a)(1) of this section shall be carried out.

(d) If the operation in which cargo gear is engaged never utilizes more than a fraction of the safe working load rating, the owner may, at his option, have said gear certificated for, and limited in operation to, a lesser maximum safe working load: Provided, however, That the gear concerned is physically capable of operation at the original load rating and the load reduction is not for the purpose of avoiding correction of any deficiency.

(e) In no case shall safe working loads be increased beyond the original design limitations unless such increase is based on engineering calculations by or acceptable to the accredited certification agency, and all necessary structural changes are carried out.

§ 1919.15 Periodic tests, examinations and inspections.

After being taken into use, every hoisting machine, all fixed gear aboard vessels accessory thereto and loose gear used in connection therewith shall be tested, thoroughly examined or inspected as follows:

(a) Derricks with their winches and accessory gear, including the attachments, as a unit; and cranes and other hoisting machines with their accessory gear, as a unit, shall be tested and thoroughly examined every 5 years in the manner set forth in subpart E of this part.

(b) Derricks, their permanent attachments and any other fixed gear, the dismantling of which is especially difficult, shall be visually inspected every twelve months. In order to facilitate such inspection, all derricks shall be lowered.

(c) All hoisting machines (e.g., cranes, winches, blocks, shackles, and all other accessory gear) not included in paragraph (b) of this section shall be thoroughly examined every 12 months by means of a visual examination, supplemented as necessary by other means, such as a hammer test or with electronic, ultrasonic, or other nondestructive methods, carried out as carefully as conditions permit in order to arrive at a reliable conclusion as to the safety of the parts examined. Particular attention shall be paid to the suitability for continued use of all swivels and the pins and bushings of blocks. If necessary, parts of the machines or gear shall be dismantled. If blocks are disassembled, all shell bolt nuts shall be securely locked upon reassembly.

(d) Where a derrick or crane is mounted on a barge hull, and ballast tanks within the hull are used to facilitate use of the derrick or crane, or uncontrolled free surface may be a factor, each annual inspection or examination, as required, shall include such inspection as is necessary for the purpose of determining the integrity of any internals contributing to stability under conditions of use. The owner shall provide the accredited person with necessary information on any ballasting arrangements required.

(e) Annual inspection or examination, as required, shall include, among other things, examination of the following:

(1) Derrick heel attachment points. Heel pins may, if possible, be examined by nondestructive examination.

(2) Shrouds and stays necessary in the use of the gear, together with attachment points.

(3) Deck fittings for the securing of vangs, topping lifts, and/or preventers.

(4) Means of attachment to the hull of “A” frame or other fixed derrick or crane structure and of mobile types of equipment permanently placed aboard the barge or vessel.

(5) Clamshell buckets or other similar equipment, such as magnets, etc., used in conjunction with a derrick or crane mounted aboard a vessel, with particular attention to closing line wires and sheaves. The accredited person may supplement such examination by requesting any operational tests he may deem appropriate.

(6) Winch and other operating drums for excessive wear or defect.

[39 FR 22096, June 19, 1974, as amended at 76 FR 33610, June 8, 2011]

§ 1919.16 Heat treatment.

(a) All chains (other than bridle chains attached to derricks or masts), rings, hooks, shackles, and swivels made of wrought iron, which are used in hoisting or lowering, shall be annealed in accordance with § 1919.36 at the following intervals:

(1) Half-inch and smaller chains, rings, hooks, shackles and swivels in general use, at least once every six months; and

(2) All other chains, rings, hooks, shackles, and swivels in general use, at least once every twelve months.

(3) In the case of gear used solely on lifting machinery worked by hand, twelve months shall be substituted for six months in paragraph (a)(1) of this section and two years for twelve months in paragraph (a)(2) of this section.

(4) When used in this paragraph, the term “in general use” means used on fifty-two or more days in a year. In any case, however, the period between annealings shall not exceed two years.

(b) Chains, rings, hooks, shackles, and swivels made of material other than wrought iron or steel shall be heat treated when necessary in accordance with § 1919.36(b).

§ 1919.17 Exemptions from heat treatment.

Gear made of steel, or gear which contains (as in ball bearings swivels), or is permanently attached to (as with blocks) equipment made of materials which cannot be subjected to heat treatment shall be exempt from the requirements of § 1919.16. Such gear, however, shall be thoroughly examined in the manner described in § 1919.15(c).

§ 1919.18 Grace periods.

Grace periods allowed in connection with the requirements of this subpart are as follows:

(a) Annual or six-month requirements—by the end of the voyage during which they become due;

(b) Quinquennial requirements—within six months after the date when due;

(c) Grace periods shall not be deemed to extend subsequent due dates.

[39 FR 22096, June 19, 1974, as amended at 76 FR 33610, June 8, 2011]

§ 1919.19 Gear requiring welding.

Chains or other gear which have been lengthened, altered or repaired by welding shall be properly heat treated where necessary, and, before again being put into use, shall be tested and reexamined in the manner set forth in subpart E of this part.

§ 1919.20 Damaged components.

(a) Pursuant to § 1918.51(b) of this chapter, any derrick or associated permanent fitting which is deformed in service between surveys shall be subjected to proof test to determine its suitability for continued service. If a proof test indicates that the derrick or associated permanent fitting may be continued in service without repair, a note of the existing deformity shall be made on the test certificate. When, in the opinion of the accredited person, it is unsafe to conduct a proof test with an existing deformity, the derrick or associated permanent fitting shall be replaced or repaired and then subjected to proof test in accordance with subpart E of this part.

(b) Any loose gear components which are injured or deformed by a proof load shall be replaced before a certificate is issued.

(c) Any derrick, other fixed installation, or associated permanent fitting which is injured or deformed by a proof load shall be replaced or repaired and another proof load test shall be conducted without damage before a certificate is issued.

§ 1919.21 Marking and posting of safe working loads.

(a) The safe working load of the assembled gear and the minimum angle to the horizontal at which this load may be applied shall be plainly marked at the heels of all booms along with the date of the test. Where gear is certificated for use in union purchase, the union purchase safe working load shall also be plainly marked. Any limitations shall be noted in the vessel's papers.

(b) The safe working load shall be marked on all blocks used in hoisting or lowering.

(c) When the capacity of the boom of a crane or derrick has been or will be rated in accordance with the variance of its radius, the maximum safe working loads for the various working angles of the boom and the maximum and minimum radii at which the boom may be safely used shall be conspicuously posted near the controls and visible to the crane operator. Ratings may be stated in pounds. When they are stated in tons of 2,000 pounds, this fact shall be indicated.

§ 1919.22 Requirements governing braking devices and power sources.

All types of winches and cranes shall be provided with means to stop and hold the proof load in any position, and the efficiency of such means shall be demonstrated. Electric winches, electrohydraulic winches fitted with electromagnetic or hydraulic brakes at the winch, or electric cranes shall be equipped so that a failure of the electric power shall stop the motion and set the brakes without any action on the part of the operator. Current for operation of electric winches and cranes during the tests shall be taken from the vessel's circuits. Shore current may be used if it passes through the vessel's main switchboard.

§ 1919.23 Means of derrick attachment.

Appropriate measures shall be taken to prevent the foot of a derrick from being accidentally lifted from its socket or support during the test.

§ 1919.24 Limitations on use of wire rope.

(a) An eye splice made in any wire rope shall have at least three tucks with a whole strand of rope and two tucks with one-half of the wires cut out of each strand. However, this requirement shall not operate to preclude the use of another form of splice or connection which can be shown to be as efficient and which is not prohibited by part 1918 of this chapter.

(b) Except for eye splices in the ends of wires, each wire rope used in hoisting or lowering, in guying derricks, or as a topping lift, preventer or pendant shall consist of one continuous piece without knot or splice.

(c) Eyes in the ends of wire rope cargo falls shall not be formed by knots and, in single part falls, shall not be formed by wire rope clips.

(d) The ends of falls shall be secured to the winch drums by clamps, U-bolts, shackles or some other equally strong method. Fiber rope fastenings shall not be used.

(e) Wire rope shall not be used for the vessel's cargo gear if in any length of eight diameters, the total number of visible broken wires exceeds 10 percent of the total number of wires, or if the rope shows other signs of excessive wear, corrosion, or defect. Particular attention shall be given to the condition of those sections of wire rope adjacent to any terminal connections, those sections exposed to abnormal wear, and those sections not normally exposed for examination.

§ 1919.25 Limitations on use of chains.

Chains forming a part of vessel's cargo gear shall not be used when, due to stretch, the increase of length of a measured section exceeds five percent, when a link is damaged, or when other external defects are evident. Chains shall not be shortened by bolting, wiring, or knotting.