Site Feedback

Title 29

Displaying title 29, up to date as of 8/13/2026. Title 29 was last amended 8/04/2026.
eCFR Content

The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

§ 1917.119 Portable ladders.

(a) Scope and applicability. This section applies to all portable ladders, including job-made ladders for temporary use, unless otherwise specified.

(b) Standards for existing manufactured portable ladders.

(1) Rungs of manufactured portable ladders obtained before October 3, 1983, shall be capable of supporting a 200-pound (890 N) load without deformation.

(2) Rungs shall be evenly spaced from 9 to 1612 inches (22.9 to 41.9 cm), center to center.

(3) Rungs shall be continuous members between rails. Each rung of a double-rung ladder (two side rails and a center rail) shall extend the full width of the ladder.

(4) Width between side rails at the base of the ladder shall be at least 12 inches (30.48 cm) for ladders 10 feet (3.05 m) or less in overall length, and shall increase at least 14 inch (0.64 cm) for each additional 2 feet (0.61 m) of ladder length.

(c) Standards for manufactured portable ladders. Portable manufactured ladders obtained after January 21, 1998 shall bear identification indicating that they meet the appropriate ladder construction requirements of the following standards:

ANSI A14.1-1990, Safety Requirements for Portable Wood Ladders

ANSI A14.2-1990, Safety Requirements for Portable Metal Ladders

ANSI A14.5-1992, Safety Requirements for Portable Reinforced Plastic Ladders

(d) Standards for job-made portable ladders. Job-made ladders shall:

(1) Have a minimum and uniform distance between rungs of 12 inches (30.48 cm), center to center;

(2) Are capable of supporting a 250-pound (1,112 N) load without deformation; and

(3) Have a minimum width between side rails of 12 inches (30.48 cm) for ladders 10 feet (3.05 m) in height. Width between rails shall increase at least 14 inch (0.64 cm) for each additional 2 feet (0.61 m) of ladder length.

(e) Maintenance and inspection.

(1) The employer shall maintain portable ladders in safe condition. Ladders with the following defects shall not be used and either shall be tagged as unusable if kept on the premises or shall be removed from the worksite:

(i) Broken, split or missing rungs, cleats or steps;

(ii) Broken or split side rails;

(iii) Missing or loose bolts, rivets or fastenings;

(iv) Defective ropes; or

(v) Any other structural defect.

(2) Ladders shall be inspected for defects prior to each day's use, and after any occurrence, such as a fall, which could damage the ladder.

(f) Ladder usage.

(1) Ladders made by fastening rungs or devices across a single rail are prohibited.

(2) Ladders shall not be used:

(i) As guys, braces or skids; or

(ii) As platforms, runways or scaffolds.

(3) Metal and wire-reinforced ladders with wooden side rails shall not be used when employees on the ladder might come into contact with energized electrical conductors.

(4) Individual sections from different multi-sectional ladders or two or more single straight ladders shall not be tied or fastened together to achieve additional length.

(5) Except for combination ladders, self-supporting ladders shall not be used as single straight ladders.

(6) Unless intended for cantilever operation, non-self-supporting ladders shall not be used to climb above the top support point.

(7) Ladders shall extend at least 36 inches (0.91 m) above the upper support level if employees are to leave or mount the ladder at that level, except that where such extension is impractical other equivalent means such as grab bars may be used to provide a hand grip.

(8) Ladders shall be securely positioned on a level and firm base.

(9) Ladders shall be fitted with slip-resistant bases and secured at top or bottom to prevent the ladder from slipping.

(10) The employer shall direct that ladders shall be placed so that employees climbing are not exposed to injury from projecting objects or doors that open toward the ladder.

[48 FR 30909, July 5, 1983, as amended at 62 FR 40201, July 25, 1997; 65 FR 40941, June 30, 2000]