Site Feedback

Title 29

Displaying title 29, up to date as of 10/13/2026. Title 29 was last amended 10/06/2026.
New Finding Aids are now available on eCFR.gov. The Parallel Table of Authorities, Subject Index, and Agency-prepared Indexes are now online! Learn more
eCFR Content

The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. The Electronic Code of Federal Regulations (eCFR) is a continuously updated online version of the CFR. It is not an official legal edition of the CFR.

Learn more about the eCFR, its status, and the editorial process.

§ 1917.51 Hand tools.

(a) Hand tools used by employees shall be maintained in safe operating condition.

(b)

(1) Hand-held portable electric tools shall be equipped with switches that must be manually held in a closed position to operate the tool.

(2) Portable power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc needed to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc needed to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.

(c) Only cutting tools shall be used to cut metal strapping or banding used to secure cargo.