Title 46Chapter ISubchapter KPart 120 → Subpart E


Title 46: Shipping
PART 120—ELECTRICAL INSTALLATION


Subpart E—Miscellaneous Systems and Requirements


Contents
§120.520   Lifeboat winches.
§120.530   Hazardous areas.
§120.540   Elevators.
§120.550   General alarm systems.

return arrow Back to Top

§120.520   Lifeboat winches.

Each electric power operated lifeboat winch must meet §111.95 in subchapter J and §160.015 in subchapter Q of this chapter, or other standard specified by the Commandant.

return arrow Back to Top

§120.530   Hazardous areas.

(a) Electrical equipment in lockers used to store paint, oil, turpentine, or other flammable liquids must be explosion-proof or be part of an intrinsically safe system.

(b) Explosion-proof equipment and intrinsically safe systems must meet the requirements of §111.105 in subchapter J of this chapter.

return arrow Back to Top

§120.540   Elevators.

Each elevator on a vessel must meet the requirements of American National Standards Institute (ANSI) A17.1. “Safety Code for Elevators, and Escalators,” or other standard specified by the Commandant.

return arrow Back to Top

§120.550   General alarm systems.

(a) All vessels with overnight accommodations must be equipped with a general alarm system.

(b) A vessel of more than 19.8 meters (65 feet) in length with overnight accommodations for more than 49 passengers must have a general alarm that meets the requirements of §113.25 in subchapter J of this chapter.

(c) The public address system required by §121.610 of this chapter may be used to sound the general alarm signal.

return arrow Back to Top