Title 40: Protection of Environment
PART 426—GLASS MANUFACTURING POINT SOURCE CATEGORY


Subpart J—Glass Tubing (Danner) Manufacturing Subcategory


Contents
§426.100   Applicability; description of the glass tubing (Danner) manufacturing subcategory.
§426.101   Specialized definitions.
§426.102   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§§426.103-426.104   [Reserved]
§426.105   Standards of performance for new sources.
§426.106   Pretreatment standards for new sources.
§426.107   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.

Source: 40 FR 2957, Jan. 16, 1975, unless otherwise noted.

§426.100   Applicability; description of the glass tubing (Danner) manufacturing subcategory.

The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and glass tubing mechanically drawn from the furnace horizontally by means of the Danner process, which requires the intermittent quenching of cullet.

§426.101   Specialized definitions.

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces.

(c) The term “cullet” shall mean any excess glass generated in the manufacturing process.

§426.102   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
   Metric units (g/kkg of furnace pull)
TSS460.0230.0
pH(1)(1)
   English units (lb/1,000 lb of furnace pull)
TSS0.460.23
pH(1)(1)

1Within the range 6.0 to 9.0.

[40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]

§§426.103-426.104   [Reserved]

§426.105   Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
   Metric units (g/kkg of furnace pull)
TSS0.40.2
pH(1)(1)
   English units (lb/1,000 lb of furnace pull)
TSS0.00040.0002
pH(1)(1)

1Within the range 6.0 to 9.0.

§426.106   Pretreatment standards for new sources.

Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.

Pollutant or pollutant propertyPretreatment standard
pHNo limitation.
TSS      Do.

[40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]

§426.107   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.102 of this subpart for the best practicable control technology currently available (BPT).

[51 FR 25000, July 9, 1986]