Title 40Chapter ISubchapter NPart 415 → Subpart T


Title 40: Protection of Environment
PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY


Subpart T—Sodium Sulfite Production Subcategory


Contents
§415.200   Applicability; description of the sodium sulfite production subcategory.
§415.201   Specialized definitions.
§415.202   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
§415.203   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
§415.204   [Reserved]
§415.205   New source performance standards (NSPS).
§415.206   Pretreatment standards for new sources (PSNS).
§415.207   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

§415.200   Applicability; description of the sodium sulfite production subcategory.

The provisions of this subpart are applicable to discharges resulting from the production of sodium sulfite by reacting sulfur dioxide with sodium carbonate.

§415.201   Specialized definitions.

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term product shall mean sodium sulfite.

§415.202   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Subpart T—Sodium Sulfite

Pollutant or pollutant propertyBPT limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS0.0320.016
COD3.41.7
pH(1)(1)

1Within the range 6.0 to 9.0.

§415.203   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):

Subpart T—Sodium Sulfite

Pollutant or pollutant propertyBAT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (or pounds per/1,000 lb) of product
Chromium (T)0.00200.00063
Zine (T)0.00510.0015
COD3.41.7

[49 FR 33420, Aug. 22, 1984]

§415.204   [Reserved]

§415.205   New source performance standards (NSPS).

Any new source subject to this subpart must achieve the following new source performance standards (NSPS):

Subpart T—Sodium Sulfite

Pollutant or pollutant propertyNSPS effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (or pounds per/1,000 lb) of product
TSS0.0320.016
Chromium (T)0.00200.00063
Zinc (T)0.00510.0015
COD3.41.7
pH(1)(1)

1Within the range 6.0 to 9.0.

[49 FR 33421, Aug. 22, 1984]

§415.206   Pretreatment standards for new sources (PSNS).

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources (PSNS).

Subpart T—Sodium Sulfite

Pollutant or pollutant propertyPSNS effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Milligrams per liter (mg/l)
Chromium (total)1.30.42
Zinc (total)3.41.2
COD1,260630

In cases when POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations on chromium (total), zinc (total), and COD are the same as specified in §415.205.

[49 FR 33421, Aug. 22, 1984]

§415.207   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations for TSS and pH are the same as specified in §415.202.

[49 FR 33421, Aug. 22, 1984]