Title 40Chapter ISubchapter NPart 415 → Subpart L


Title 40: Protection of Environment
PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY


Subpart L—Potassium Dichromate Production Subcategory


Contents
§415.120   Applicability; description of the potassium dichromate production subcategory.
§415.121   Specialized definitions. [Reserved]
§415.122   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
§415.123   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
§415.124   Pretreatment standards for existing sources (PSES).
§415.125   New source performance standards (NSPS).
§415.126   Pretreatment standards for new sources (PSNS).

§415.120   Applicability; description of the potassium dichromate production subcategory.

The provisions of this subpart are applicable to discharges and to the introduction of pollutants resulting from the production of potassium dichromate into treatment works which are publicly owned.

§415.121   Specialized definitions. [Reserved]

§415.122   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process wastewater pollutants to navigable waters.

§415.123   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT): There shall be no discharge of process wastewater pollutants to navigable waters.

§415.124   Pretreatment standards for existing sources (PSES).

Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources (PSES):

Subpart L—Potassium Dichromate

Pollutant or pollutant propertyPSES limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Milligrams per liter (mg/l)
Hexavalent chromium0.250.090
Total chromium3.01.0

§415.125   New source performance standards (NSPS).

Any new source subject to this subpart must achieve the following new source performance standards (NSPS): There shall be no discharge of process wastewater pollutants to navigable waters.

§415.126   Pretreatment standards for new sources (PSNS).

Except as provided in §403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources (PSNS): There shall be no discharge of process wastewater pollutants to navigable waters.