Title 40Chapter ISubchapter NPart 415 → Subpart BB


Title 40: Protection of Environment
PART 415—INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY


Subpart BB—Sodium Bisulfite Production Subcategory


Contents
§415.540   Applicability; description of the sodium bisulfite production subcategory.
§415.541   Specialized definitions.
§415.542   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
§415.543   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
§415.544   [Reserved]
§415.545   New source performance standards (NSPS).
§415.546   Pretreatment standards for new sources (PSNS).
§415.547   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

§415.540   Applicability; description of the sodium bisulfite production subcategory.

This subpart applies to discharges to waters of the United States and introduction of pollutants into publicly owned treatment works resulting from the production of sodium bisulfite.

§415.541   Specialized definitions.

For the purposes of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term product means sodium bisulfite.

§415.542   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Subpart BB—Sodium Bisulfite

Pollutant or pollutant propertyBPT effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Kg/kkg (or pounds per 1,000 lb) of product
TSS0.320.080
COD3.80.95
Chromium (T)0.00200.00063
Zinc (T)0.00510.0015
pH(1)(1)

1Within the range 6.0 to 9.0.

§415.543   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT): The limitations on COD, Chromium(T), and Zinc(T) are the same as specified in §415.542.

§415.544   [Reserved]

§415.545   New source performance standards (NSPS).

Any new source subject to this subpart must achieve the following new source performance standards (NSPS): The limitations are the same as specified in §415.542.

§415.546   Pretreatment standards for new sources (PSNS).

Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following Pretreatment Standards for New Sources (PSNS):

Subpart BB—Sodium Bisulfite

Pollutant or pollutant propertyPSNS effluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days
Milligrams per liter
Chromium (T)1.30.42

In cases where POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations for Chromium (T) are the same as specified in §415.545.

[47 FR 55227, Dec. 8, 1982]

§415.547   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in 40 CFR 125.30 through 125.32 any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations are the same for TSS and pH as specified in §414.542.