Title 40Chapter ISubchapter NPart 408 → Subpart O


Title 40: Protection of Environment
PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY


Subpart O—Fish Meal Processing Subcategory


Contents
§408.150   Applicability; description of the fish meal processing subcategory.
§408.151   Specialized definitions.
§408.152   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§408.153   [Reserved]
§408.154   Pretreatment standards for existing sources.
§408.155   Standards of performance for new sources.
§408.156   Pretreatment standards for new sources.
§408.157   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Source: 40 FR 55781, Dec. 1, 1975, unless otherwise noted.

§408.150   Applicability; description of the fish meal processing subcategory.

The provisions of this subpart are applicable to discharges resulting from the processing of menhaden on the Gulf and Atlantic Coasts and the processing of anchovy on the West Coast into fish meal, oil and solubles.

§408.151   Specialized definitions.

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.

§408.152   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) Any menhaden or anchovy fish meal reduction facility which utilizes a solubles plant to process stick water or bail water shall meet the following limitations.

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of seafood)
BOD57.03.9
TSS3.71.5
Oil and grease1.40.76
pH(1)(1)
English units (pounds per 1,000 lb of seafood)
BOD57.03.9
TSS3.71.5
Oil and grease1.40.76
pH(1)(1)

1Within the range 6.0 to 9.0.

(b) Any menhaden or anchovy fish meal reduction facility not covered under §408.152(a) shall meet the following limitations:

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of seafood)
BOD53.52.8
TSS2.61.7
Oil and grease3.21.4
pH(1)(1)
English units (lb/1,000 lb of seafood)
BOD53.52.8
TSS2.61.7
Oil and grease3.21.4
pH(1)(1)

1Within the range 6.0 to 9.0.

[40 FR 55781, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33943, June 29, 1995]

§408.153   [Reserved]

§408.154   Pretreatment standards for existing sources.

Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.

Pollutant or pollutant propertyPretreatment standard
BOD5No limitation.
TSS      Do.
pH      Do.
Oil and grease      Do.

[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33943, June 29, 1995]

§408.155   Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of seafood)
BOD56.73.8
TSS3.71.5
Oil and grease1.40.76
pH(1)(1)
English units (pounds per 1,000 lb of seafood)
BOD56.73.8
TSS3.71.5
Oil and grease1.40.76
pH(1)(1)

1Within the range 6.0 to 9.0.

[40 FR 55781, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976]

§408.156   Pretreatment standards for new sources.

Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:

Pollutant or pollutant propertyPretreatment standard
BOD5No limitation.
TSS      Do.
pH      Do.
Oil and grease      Do.

[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]

§408.157   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.152 of this subpart for the best practicable control technology currently available (BPT).

[51 FR 24997, July 9, 1986]