Title 40Chapter ISubchapter NPart 408 → Subpart AF


Title 40: Protection of Environment
PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY


Subpart AF—Non-Alaskan Herring Fillet Processing Subcategory


Contents
§408.320   Applicability; description of the non-Alaskan herring fillet processing subcategory.
§408.321   Specialized definitions.
§408.322   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§408.323   [Reserved]
§408.324   Pretreatment standards for existing sources.
§408.325   Standards of performance for new sources.
§408.326   Pretreatment standards for new sources.
§408.327   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Source: 40 FR 55799, Dec. 1, 1975, unless otherwise noted.

§408.320   Applicability; description of the non-Alaskan herring fillet processing subcategory.

The provisions of this subpart are applicable to discharges resulting from the processing of herring fillets outside of Alaska.

§408.321   Specialized definitions.

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term seafood shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.

§408.322   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of seafood)
TSS3224
Oil and grease2710
pH(1)(1)
English units (lb/1,000 lb of seafood)
TSS3224
Oil and grease2710
pH(1)(1)

1Within the range 6.0 to 9.0.

[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§408.323   [Reserved]

§408.324   Pretreatment standards for existing sources.

Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.

Pollutant or pollutant propertyPretreatment standard
BOD5No limitation.
TSS      Do.
pH      Do.
Oil and grease      Do.

[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§408.325   Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
Metric units (kg/kkg of seafood)
BOD51615
TSS7.05.2
Oil and grease2.91.1
pH(1)(1)
English units (lb/1,000 lb of seafood)
BOD51615
TSS7.05.2
Oil and grease2.91.1
pH(1)(1)

1Within the range 6.0 to 9.0.

§408.326   Pretreatment standards for new sources.

Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:

Pollutant or pollutant propertyPretreatment standard
BOD5No limitation.
TSS      Do.
pH      Do.
Oil and grease      Do.

[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]

§408.327   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §408.322 of this subpart for the best practicable control technology currently available (BPT).

[51 FR 24997, July 9, 1986]