Title 49Subtitle BChapter VPart 572Subpart M → §572.115


Title 49: Transportation
PART 572—ANTHROPOMORPHIC TEST DEVICES
Subpart M—Side Impact Hybrid Dummy 50th Percentile Male


§572.115   Lumbar spine and pelvis.

The specifications and test procedure for the lumbar spine and pelvis are identical to those for the SID dummy as set forth in §572.42 except that the reference to the SID device found in §572.42(a), (SA-SID-M001A revision A, dated May 18, 1994) does not apply and the reference to the SID/HIII (SA-SIDH3-M001, dated April 19, 1997) is applied in its place.