Title 49Subtitle BChapter ISubchapter DPart 195Subpart C → §195.134


Title 49: Transportation
PART 195—TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE
Subpart C—Design Requirements


§195.134   Leak detection.

(a) Scope. This section applies to each hazardous liquid pipeline transporting liquid in single phase (without gas in the liquid).

(b) General. (1) For each pipeline constructed prior to October 1, 2019. Each pipeline must have a system for detecting leaks that complies with the requirements in §195.444 by October 1, 2024.

(2) For each pipeline constructed on or after October 1, 2019. Each pipeline must have a system for detecting leaks that complies with the requirements in §195.444 by October 1, 2020.

(c) CPM leak detection systems. A new computational pipeline monitoring (CPM) leak detection system or replaced component of an existing CPM system must be designed in accordance with the requirements in section 4.2 of API RP 1130 (incorporated by reference, see §195.3) and any other applicable design criteria in that standard.

(d) Exception. The requirements of paragraph (b) of this section do not apply to offshore gathering or regulated rural gathering lines.

[Amdt. 195-102, 84 FR 52295, Oct. 1, 2019]