e-CFR data is current as of January 19, 2021 |
Title 49 → Subtitle B → Chapter I → Subchapter D → Part 192 → Subpart C → §192.115 |
Title 49: Transportation
PART 192—TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS
Subpart C—Pipe Design
The temperature derating factor to be used in the design formula in §192.105 is determined as follows:
Gas temperature in degrees Fahrenheit (Celsius) | Temperature derating factor (T) |
---|---|
250 °F (121 °C) or less | 1.000 |
300 °F (149 °C) | 0.967 |
350 °F (177 °C) | 0.933 |
400 °F (204 °C) | 0.900 |
450 °F (232 °C) | 0.867 |
For intermediate gas temperatures, the derating factor is determined by interpolation.
[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-85, 63 FR 37502, July 13, 1998]