e-CFR data is current as of January 19, 2021 |
Title 47 → Chapter I → Subchapter A → Part 15 → Subpart C → §15.237 |
Title 47: Telecommunication
PART 15—RADIO FREQUENCY DEVICES
Subpart C—Intentional Radiators
(a) The intentional radiator shall be restricted to use as an auditory assistance device.
(b) Emissions from the intentional radiator shall be confined within a band 200 kHz wide centered on the operating frequency. The 200 kHz band shall lie wholly within the above specified frequency ranges.
(c) The field strength within the permitted 200 kHz band shall not exceed 80 millivolts/meter at 3 meters. The field strength of any emissions radiated on any frequency outside of the specified 200 kHz band shall not exceed the general radiated emissions limits specified in §15.209. The emission limits in this paragraph are based on measurement instrumentation employing an average detector. The provisions in §15.35 for limiting peak emissions apply.
[54 FR 17714, Apr. 25, 1989, as amended at 57 FR 13048, Apr. 15, 1992; 78 FR 34927, June 11, 2013]