Title 46Chapter ISubchapter HPart 72Subpart 72.20 → §72.20-50


Title 46: Shipping
PART 72—CONSTRUCTION AND ARRANGEMENT
Subpart 72.20—Accommodations for Officers and Crew


§72.20-50   Heating and cooling.

(a) All manned spaces must be adequately heated and cooled in a manner suitable to the purpose of the space.

(b) The heating and cooling system for accommodations must be capable of maintaining a temperature of 21 °C (70 °F) under normal operating conditions without curtailing ventilation.

(c) Radiators and other heating apparatus must be so placed and shielded, where necessary, to avoid risk of fire, danger or discomfort to the occupants. Pipes leading to radiators or heating apparatus must be insulated where those pipes create a hazard to persons occupying the space.