Title 40Chapter ISubchapter IPart 261Subpart BB → §261.1055


Title 40: Protection of Environment
PART 261—IDENTIFICATION AND LISTING OF HAZARDOUS WASTE
Subpart BB—Air Emission Standards for Equipment Leaks


§261.1055   Standards: Sampling connection systems.

(a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed-vent system. This system shall collect the sample purge for return to the process or for routing to the appropriate treatment system. Gases displaced during filling of the sample container are not required to be collected or captured.

(b) Each closed-purge, closed-loop, or closed-vent system as required in paragraph (a) of this section shall meet one of the following requirements:

(1) Return the purged process fluid directly to the process line;

(2) Collect and recycle the purged process fluid; or

(3) Be designed and operated to capture and transport all the purged process fluid to a material management unit that complies with the applicable requirements of §§261.1084 through 264.1086 of this subpart or a control device that complies with the requirements of §261.1060 of this subpart.

(c) In-situ sampling systems and sampling systems without purges are exempt from the requirements of paragraphs (a) and (b) of this section.