§250.520   How often do I have to monitor for casing pressure?

You must monitor for casing pressure in your well according to the following table:

If you have .  .  .you must monitor .  .  .with a minimum one pressure data point recorded per .  .  .
(a) fixed platform wells,monthly,month for each casing.
(b) subsea wells,continuously,day for the production casing.
(c) hybrid wells,continuously,day for each riser and/or the production casing.
(d) wells operating under a casing pressure request on a manned fixed platform,daily,day for each casing.
(e) wells operating under a casing pressure request on an unmanned fixed platform,weekly,week for each casing.

[76 FR 64462, Oct. 18, 2011. Redesignated at 77 FR 50894, Aug. 22, 2012]