Title 10Chapter IISubchapter DPart 429Subpart B → §429.46


Title 10: Energy
PART 429—CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT
Subpart B—Certification


§429.46   Commercial clothes washers.

(a) Sampling plan for selection of units for testing. (1) The requirements of §429.11 are applicable to commercial clothes washers; and

(2) For each basic model of commercial clothes washers, a sample of sufficient size shall be randomly selected and tested to ensure that—

(i) Any represented value of the water factor or other measure of energy or water consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

eCFR graphic er07mr11.109.gif

View or download PDF

Or,

(B) The upper 9712 percent confidence limit (UCL) of the true mean divided by 1.05, where:

eCFR graphic er02my11.078.gif

View or download PDF

and

(ii) Any represented value of the modified energy factor or other measure of energy or water consumption of a basic model for which consumers would favor higher values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

eCFR graphic er07mr11.111.gif

View or download PDF

Or,

(B) The lower 9712 percent confidence limit (LCL) of the true mean divided by 0.95, where:

eCFR graphic er02my11.079.gif

View or download PDF

(b) Certification reports. (1) The requirements of §429.12 are applicable to commercial clothes washers; and

(2) Pursuant to §429.12(b)(13), a certification report shall include the following public product-specific information:

(i) If testing was conducted using Appendix J1 to subpart B of part 430 of this chapter: The modified energy factor (MEF) in cubic feet per kilowatt hour per cycle (cu ft/kWh/cycle); and the water factor (WF) in gallons per cubic feet per cycle (gal/cu ft/cycle);

(ii) If testing was conducted using Appendix J2 to subpart B of part 430 of this chapter: The modified energy factor (MEFJ2) in cu ft/kWh/cycle and the integrated water factor (IWF) in gal/cu ft/cycle.

[76 FR 12451, Mar. 7, 2011; 76 FR 24777, May 2, 2011, as amended at 79 FR 71630, Dec. 3, 2014]