§429.19   Dishwashers.

(a) Sampling plan for selection of units for testing. (1) The requirements of §429.11 are applicable to dishwashers; and

(2) For each basic model of dishwashers, a sample of sufficient size shall be randomly selected and tested to ensure that—

(i) Any represented value of estimated annual operating cost, energy or water consumption or other measure of energy or water consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

eCFR graphic er07mr11.035.gif

View or download PDF

Or,

(B) The upper 9712 percent confidence limit (UCL) of the true mean divided by 1.05, where:

eCFR graphic er02my11.041.gif

View or download PDF

and

(ii) Any represented value of the energy or water factor or other measure of energy or water consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:

(A) The mean of the sample, where:

eCFR graphic er07mr11.037.gif

View or download PDF

Or,

(B) The lower 9712 percent confidence limit (LCL) of the true mean divided by 0.95, where:

eCFR graphic er02my11.042.gif

View or download PDF

(b) Certification reports. (1) The requirements of §429.12 are applicable to dishwashers; and

(2) Pursuant to §429.12(b)(13), a certification report shall include the following public product-specific information: The estimated annual energy use in kilowatt hours per year (kWh/yr) and the water consumption in gallons per cycle.

(3) Pursuant to §429.12(b)(13), a certification report shall include the following additional product-specific information the capacity in number of place settings as specified in ANSI/AHAM DW-1-2010 (incorporated by reference, see §429.4), presence of a soil sensor (if yes, the number of cycles required to reach calibration), the water inlet temperature used for testing in degrees Fahrenheit ( °F), the cycle selected for energy testing and whether that cycle is soil-sensing, the options selected for the energy test, and presence of a built-in water softening system (if yes, the energy use in kilowatt-hours and the water use in gallons required for each regeneration of the water softening system, the number of regeneration cycles per year, and data and calculations used to derive these values).

[76 FR 12451, Mar. 7, 2011; 76 FR 24766, May 2, 2011, as amended at 77 FR 31962, May 30, 2012; 77 FR 65977, Oct. 31, 2012; 81 FR 90118, Dec. 13, 2016]