Title 10Chapter IPart 71Subpart E → §71.61


Title 10: Energy
PART 71—PACKAGING AND TRANSPORTATION OF RADIOACTIVE MATERIAL
Subpart E—Package Approval Standards


§71.61   Special requirements for Type B packages containing more than 105A2.

A Type B package containing more than 105A2 must be designed so that its undamaged containment system can withstand an external water pressure of 2 MPa (290 psi) for a period of not less than 1 hour without collapse, buckling, or inleakage of water.

[69 FR 3795, Jan. 26, 2004]