Title 40Chapter ISubchapter CPart 60Subpart EEEE → Appendix


Title 40: Protection of Environment
PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (CONTINUED)
Subpart EEEE—Standards of Performance for Other Solid Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which Modification or Reconstruction is Commenced on or After June 16, 2006


Table 2 to Subpart EEEE of Part 60—Operating Limits for Incinerators and Wet Scrubbers

As stated in §60.2916, you must comply with the following:

For these operating
parameters
You must establish these operating limitsAnd monitoring using these minimum frequencies
Data measurementData recordingAveraging time
1. Charge rateMaximum charge rateContinuousEvery hourDaily for batch units. 3-hour rolling for continuous and intermittent unitsa.
2. Pressure drop across the wet scrubber or amperage to wet scrubberMinimum pressure drop or amperageContinuousEvery 15 minutes3-hour rollinga.
3. Scrubber liquor flow rateMinimum flow rateContinuousEvery 15 minutes3-hour rollinga.
4. Scrubber liquor pHMinimum pHContinuousEvery 15 minutes3-hour rollinga.

aCalculated each hour as the average of the previous 3 operating hours.