Home
gpo.gov
govinfo.gov

e-CFR Navigation Aids

Browse

Simple Search

Advanced Search

 — Boolean

 — Proximity

 

Search History

Search Tips

Corrections

Latest Updates

User Info

FAQs

Agency List

Incorporation By Reference

eCFR logo

Related Resources

Electronic Code of Federal Regulations

We invite you to try out our new beta eCFR site at https://ecfr.federalregister.gov. We have made big changes to make the eCFR easier to use. Be sure to leave feedback using the Feedback button on the bottom right of each page!

e-CFR data is current as of November 23, 2020

Title 40Chapter ISubchapter CPart 60Subpart BBBB → Appendix


Title 40: Protection of Environment
PART 60—STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES (CONTINUED)
Subpart BBBB—Emission Guidelines and Compliance Times for Small Municipal Waste Combustion Units Constructed on or Before August 30, 1999


Table 8 to Subpart BBBB of Part 60—Model Rule—Requirements for Stack Tests

To measure the following pollutants Use the following methods in appendix A of this part to determine the sampling location Use the following methods in appendix A of this part to measure pollutant concentration Also note the following additional information
1. Organics
Dioxins/FuransMethod 1Method 23aThe minimum sampling time must be 4 hours per test run while the municipal waste combustion unit is operating at full load.
2. Metals
CadmiumMethod 1Method 29aCompliance testing must be performed while the municipal waste combustion unit is operating at full load.
LeadMethod 1Method 29aCompliance testing must be performed while the municipal waste combustion unit is operating at full load.
MercuryMethod 1Method 29aCompliance testing must be performed while the municipal waste combustion unit is operating at full load.
OpacityMethod 9Method 9Use Method 9 to determine compliance with opacity limits. 3-hour observation period (thirty 6-minute averages).
Particulate MatterMethod 1Method 5 or 29The minimum sample volume must be 1.0 cubic meters. The probe and filter holder heating systems in the sample train must be set to provide a gas temperature no greater than 160 ±14 °C. The minimum sampling time is 1 hour.
3. Acid Gasesb
Hydrogen ChlorideMethod 1Method 26 or 26AaTest runs must be at least 1 hour long while the municipal waste combustion unit is operating at full load.
4. Otherb
Fugitive AshNot applicableMethod 22 (visible emissions)The three 1-hour observation period must include periods when the facility transfers fugitive ash from the municipal waste combustion unit to the area where the fugitive ash is stored or loaded into containers or trucks.

aMust simultaneously measure oxygen (or carbon dioxide) using Method 3A or 3B in appendix A of this part.

bUse CEMS to test sulfur dioxide, nitrogen oxide, and carbon monoxide. Stack tests are not required except for quality assurance requirements in appendix F of this part.

Need assistance?