e-CFR banner

Home
gpo.gov
govinfo.gov

e-CFR Navigation Aids

Browse

Simple Search

Advanced Search

 — Boolean

 — Proximity

 

Search History

Search Tips

Corrections

Latest Updates

User Info

FAQs

Agency List

Incorporation By Reference

eCFR logo

Related Resources

 

Electronic Code of Federal Regulations

e-CFR data is current as of December 5, 2019

Title 40Chapter ISubchapter CPart 63Subpart WWWW → Appendix


Title 40: Protection of Environment
PART 63—NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED)
Subpart WWWW—National Emissions Standards for Hazardous Air Pollutants: Reinforced Plastic Composites Production


Table 12 to Subpart WWWW of Part 63—Data Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs/Ton Organic HAP Emissions Limit on a Per Line Basis

As required in §63.5865(b), in order to comply with a lbs/ton organic HAP emissions limit for continuous lamination lines and continuous casting lines you must determine the data in the following table:

For each line where the wet- out area .  .  .And the oven .  .  .You must determine .  .  .
1. Is uncontrolleda. Is uncontrolledi. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual uncontrolled oven organic HAP emissions, and
iii. Annual neat resin plus and neat gel coat plus applied.
2. Has an enclosure that is not a PTE and the captured organic HAP emissions are controlled by an add-on control devicea. Is uncontrolledi. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual controlled wet-out area organic HAP emissions,
iii. Annual uncontrolled oven organic HAP emissions,
   iv. The capture efficiency of the wet-out area enclosure,
v. The destruction efficiency of the add-on control device, and
vi. The amount of neat resin plus and neat gel coat plus applied.
3. Has an enclosure that is a PTE, and the captured organic HAP emissions are controlled by an add-on control devicea. Is uncontrolledi. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual controlled wet-out area organic HAP emissions,
iii. Annual uncontrolled oven organic HAP emissions,
   iv. That the wet-out area enclosure meets the requirements of EPA Method 204 of appendix M to 40 CFR part 51 for a PTE,
v. The destruction efficiency of the add-on control device, and
vi. The amount of neat resin plus and neat gel coat plus applied.
4. Is uncontrolleda. Is controlled by an add-on control devicei. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual uncontrolled oven organic HAP emissions,
iii. Annual controlled oven organic HAP emissions,
   iv. The capture efficiency of the oven,
v. The destruction efficiency of the add-on control device, and
vi. The amount of neat resin plus and neat gel coat plus applied.
5. Has an enclosure that is not a PTE and the captured organic HAP emissions are controlled by an add-on control devicea. Is controlled by an add-on control devicei. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual controlled wet-out area organic HAP emissions,
iii. Annual uncontrolled oven organic HAP emissions,
   iv. Annual controlled oven organic HAP emissions,
v. The capture efficiency of the wet-out area enclosure,
vi. The capture efficiency of the oven,
   vii. The destruction efficiency of the add-on control device, and
viii. The amount of neat resin plus and neat gel coat plus applied.
6. Has an enclosure that is a PTE, and the captured organic HAP emissions are controlled by add-on control devicea. Is controlled by an add-on control devicei. That the wet-out area enclosure meets the requirements of EPA Method 204 of appendix M to 40 CFR part 51 for a PTE,
ii. The capture efficiency of the oven,
iii. Inlet organic HAP emissions to the an add-on control device, and
   iv. Outlet organic HAP emissions from the add-on control device.

Need assistance?