Title 40Chapter ISubchapter NPart 426 → Subpart H


Title 40: Protection of Environment
PART 426—GLASS MANUFACTURING POINT SOURCE CATEGORY


Subpart H—Glass Container Manufacturing Subcategory


Contents
§426.80   Applicability; description of the glass container manufacturing subcategory.
§426.81   Specialized definitions.
§426.82   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§§426.83-426.84   [Reserved]
§426.85   Standards of performance for new sources.
§426.86   Pretreatment standards for new sources.
§426.87   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.

Source: 40 FR 2956, Jan. 16, 1975, unless otherwise noted.

return arrow Back to Top

§426.80   Applicability; description of the glass container manufacturing subcategory.

The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and mechanically processed into glass containers.

return arrow Back to Top

§426.81   Specialized definitions.

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces.

(c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407.

return arrow Back to Top

§426.82   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
   Metric units (g/kkg of furnace pull)
Oil60.030.0
TSS140.070.0
pH(1)(1)
   English units (lb/1,000 lb of furnace pull)
Oil0.060.03
TSS0.140.07
pH(1)(1)

1Within the range 6.0 to 9.0.

[40 FR 2956, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]

return arrow Back to Top

§§426.83-426.84   [Reserved]

return arrow Back to Top

§426.85   Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
   Metric units (g/kkg of furnace pull)
Oil1.60.8
TSS1.60.8
pH(1)(1)
   English units (lb/1,000 lb of furnace pull)
Oil0.00160.0008
TSS0.00160.0008
pH(1)(1)

1Within the range 6.0 to 9.0.

return arrow Back to Top

§426.86   Pretreatment standards for new sources.

Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established.

Pollutant or pollutant propertyPretreatment standards
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed—
   Metric units (g/kkg of furnace pull)
Oil (animal and vegetable)(1)(1)
Oil (mineral)60.030.0
TSS(1)(1)
pH(1)(1)
   English units (lb/1,000 lb of furnace pull)
Oil (animal and vegetable)(1)(1)
Oil (mineral)0.060.03
TSS(1)(1)
pH(1)(1)

1No limitation.

[40 FR 2956, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]

return arrow Back to Top

§426.87   Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.82 of this subpart for the best practicable control technology currently available (BPT).

[51 FR 25000, July 9, 1986]

return arrow Back to Top