As stated in §60.2916, you must comply with the following:
For these operating parameters | You must establish these operating limits | And monitoring using these minimum frequencies | ||
---|---|---|---|---|
Data measurement | Data recording | Averaging time | ||
1. Charge rate | Maximum charge rate | Continuous | Every hour | Daily for batch units. 3-hour rolling for continuous and intermittent unitsa. |
2. Pressure drop across the wet scrubber or amperage to wet scrubber | Minimum pressure drop or amperage | Continuous | Every 15 minutes | 3-hour rollinga. |
3. Scrubber liquor flow rate | Minimum flow rate | Continuous | Every 15 minutes | 3-hour rollinga. |
4. Scrubber liquor pH | Minimum pH | Continuous | Every 15 minutes | 3-hour rollinga. |
aCalculated each hour as the average of the previous 3 operating hours.