About GPO   |   Newsroom/Media   |   Congressional Relations   |   Inspector General   |   Careers   |   Contact   |   askGPO   |   Help  
 
Home   |   Customers   |   Vendors   |   Libraries  

The Electronic Code of Federal Regulations (e-CFR) is a regularly updated, unofficial editorial compilation of CFR material and Federal Register amendments produced by the National Archives and Records Administration's Office of the Federal Register (OFR) and the Government Printing Office.

Parallel Table of Authorities and Rules for the Code of Federal Regulations and the United States Code
Text | PDF

Find, review, and submit comments on Federal rules that are open for comment and published in the Federal Register using Regulations.gov.

Purchase individual CFR titles from the U.S. Government Online Bookstore.

Find issues of the CFR (including issues prior to 1996) at a local Federal depository library.

[2]
 
 

Electronic Code of Federal Regulations

e-CFR Data is current as of September 30, 2014

Title 10Chapter IPart 20Subpart A → §20.1004


Title 10: Energy
PART 20—STANDARDS FOR PROTECTION AGAINST RADIATION
Subpart A—General Provisions


§20.1004   Units of radiation dose.

(a) Definitions. As used in this part, the units of radiation dose are:

Gray (Gy) is the SI unit of absorbed dose. One gray is equal to an absorbed dose of 1 Joule/kilogram (100 rads).

Rad is the special unit of absorbed dose. One rad is equal to an absorbed dose of 100 ergs/gram or 0.01 joule/kilogram (0.01 gray).

Rem is the special unit of any of the quantities expressed as dose equivalent. The dose equivalent in rems is equal to the absorbed dose in rads multiplied by the quality factor (1 rem=0.01 sievert).

Sievert is the SI unit of any of the quantities expressed as dose equivalent. The dose equivalent in sieverts is equal to the absorbed dose in grays multiplied by the quality factor (1 Sv=100 rems).

(b) As used in this part, the quality factors for converting absorbed dose to dose equivalent are shown in table 1004(b).1.

Table 1004(b).1—Quality Factors and Absorbed Dose Equivalencies

Type of radiationQuality factorAbsorbed dose equal to a unit dose equivalenta
(Q)
X-, gamma, or beta radiation11
Alpha particles, multiple-charged particles, fission fragments and heavy particles of unknown charge200.05
Neutrons of unknown energy100.1
High-energy protons100.1

aAbsorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 sievert.

(c) If it is more convenient to measure the neutron fluence rate than to determine the neutron dose equivalent rate in rems per hour or sieverts per hour, as provided in paragraph (b) of this section, 1 rem (0.01 Sv) of neutron radiation of unknown energies may, for purposes of the regulations in this part, be assumed to result from a total fluence of 25 million neutrons per square centimeter incident upon the body. If sufficient information exists to estimate the approximate energy distribution of the neutrons, the licensee may use the fluence rate per unit dose equivalent or the appropriate Q value from table 1004(b).2 to convert a measured tissue dose in rads to dose equivalent in rems.

Table 1004(b).2—Mean Quality Factors, Q, and Fluence per Unit Dose Equivalent for Monoenergetic Neutrons

  Neutron energy (MeV)Quality factora (Q)Fluence per unit dose equivalentb (neutrons cm−2 rem −1)
(thermal)2.5×10−82  980×106
   1×10−72  980×106
   1×10−62  810×106
   1×10−52  810×106
   1×10−42  840×106
   1×10−32  980×106
   1×10−22.51010×106
   1×10−17.5  170×106
   5×10−111   39×106
   111   27×106
   2.59   29×106
   58   23×106
   77   24×106
   106.5   24×106
   147.5   17×106
   208   16×106
   407   14×106
   605.5   16×106
   1×1024   20×106
   2×1023.5   19×106
   3×1023.5   16×106
   4×1023.5   14×106

aValue of quality factor (Q) at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom.

bMonoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom.



For questions or comments regarding e-CFR editorial content, features, or design, email ecfr@nara.gov.
For questions concerning e-CFR programming and delivery issues, email webteam@gpo.gov.